L x W x H in cm - 45.0 x 35.5 x 11.5,
Size
Features
- Advance ESU, 300W
- Monopolar+Bipolar+Saline Resection
- Saline Resection Mode : Saline Plasma Bipolar Cut & Coag with reusable Bipolar working element & loops.
- MONOPOLAR CUT :
- Pure Sine wave 390 kHz
- Sp Cut - Programmable Pulse or continues output,300 W at 300 Ω, CF 1.5
- Pure - Continues output, 300 W at 300 Ω, CF 1.5
- Blend - Bursts repeating at 29 kHz 55% ON cycle,200 W at 300 Ω, CF 2.5
- Endo - Pulse output, 300W at 300 Ω, CF 1.5
- MONOPOLAR COAG :
- Damped Sine wave 460 kHz
- Soft -Repetition Frequency 62 kHz, 120 W at 500 Ω, CF 5.0
- Fulgurate LCF -Repetition Frequency 42 kHz, 120 W at 500 Ω, CF 6.2
- Fulgurate HCF-Repetition Frequency 34 kHz, 120 W at 500 Ω, CF 7.0
- Randomized Spray - Randomized Repetition Frequency
- 34 kHz < f < 50 kHz, 120 W at 500 Ω, CF 8.0
- BIPOLAR : Pure Sine wave 440 kHz
- Micro -Lower output voltage, 95 W at 100 Ω, CF 1.5
- Macro - Higher output voltage, 95 W at 100 Ω, CF 1.5
- SALINE RESECTION :
- SIX Modes
- Saline Cut Modes: 390 kHz
- Cut I : Continues output 300 W at 100 Ω, CF 1.5, Low Volt
- Cut II: Continues output 300 W at 100 Ω, CF 1.5, Medium Volt
- Cut III : Continues output 300 W at 100 Ω, CF 1.5, High Volt
- Saline Coag Modes: 440kHz
- Soft: Continues output 200 W at 100 Ω, CF 1.5, Low Voltage
- Standard: Continues output 200 W at 100 Ω, CF 1.5, Medium Volt
- Force: Continues output 200 W at 100 Ω, CF 1.5, High Volt
- FEEDBACK SYSTEM:
- 3 Microprocessor Controlled 6SENSE Technology with sampling rate above 4000 sense/second
- Maximum output power deviation < 15% or 5 watts, whichever is greater at any setting with PER-98
Description
- Saline Resection Mode : Saline Plasma Bipolar Cut & Coag with reusable Bipolar working element & loops.
- Bipolar Cut & Coag Mode : Bipolar Coaglution & Cutting of Tissue by Shalya Bipolar Scalpel (Desiccator)
- 6SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology.
- PREM : Patient Return Electrode Monitoring gives an Alarm providing safety against the Return Electrode site burns.
- Tissue ReHold Alarm : “CL rEHOLd" (Close Rehold) is given if Insert is closed & “OP rEHOLd"(Open Rehold) in case of open.
- Randomized SPRAY Coag : Homogeneous, superficial, faster Coagulation over larger area.
- Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any.
- Upgradability : Argon Beam Coagulation, Ultrasonic Aspirator, Smoke Evacuator, Suction Irrigation module.
- User Programmable : THIRTY Surgical Programs help in setting the system after power ON.
- BiCoag Alarm : Audio feedback after completion of Bipolar Coag, reduces charring and sticking.
- Pulse/Endo Cut : Tissue feedback Pulse Interval controlled Pulse Cut for Polypectomy & Papillotomy.
- Remote Power Settings : Change mode and power from sterile field by normal Handswitch Pencil.
- AutoBip (Optional) : Automatic Start & Stop of Bipolar current by tissue sensing without foot switch activation.
- Foot Switches / Pedals : Explosion Proof (Fire Resistance) and Water Proof Foot Pedals
- Time Out Function (Optional) : Automatically stops the HF output if prolong unintended activation.
- Surgical Applications : Useful for wide range of surgical application as : Plastic, Neuro, ENT, Spine, Opthal, Laparo Surgery, Endo, GI, Ortho, Open & General Surgery, Onco, Gynecology, Hernia,GI Endocut, Papillotomy, Polypectomy, Under Water, Urology, Gynec TCRE, Hysteroscopy, Thoracotomy, Cardio Thoracic. Saline Plasma Bipolar Resection : Bipolar TURP/ TCRE / Hysteroscopy / Arthroscopic Surgery