Back
Brand Logo

Shalya - TURo Seal -300 W[Varient -SE]

In Stock

 
 

Size

L x W x H in cm - 45.0 x 35.5 x 11.5,

Features

  • Advance ESU, 300W
  • Monopolar+Bipolar+Saline Resection 
  • Saline Resection Mode : Saline Plasma Bipolar Cut & Coag with reusable Bipolar working element & loops.
  • MONOPOLAR CUT :
    • Pure Sine wave 390 kHz
    • Sp Cut - Programmable Pulse or continues output,300 W at 300 Ω, CF 1.5
    • Pure - Continues output, 300 W at 300 Ω, CF 1.5
    • Blend - Bursts repeating at 29 kHz 55% ON cycle,200 W at 300 Ω, CF 2.5
    • Endo - Pulse output, 300W at 300 Ω, CF 1.5
  • MONOPOLAR COAG :
    • Damped Sine wave 460 kHz
    • Soft -Repetition Frequency 62 kHz, 120 W at 500 Ω, CF 5.0
    • Fulgurate LCF -Repetition Frequency 42 kHz, 120 W at 500 Ω, CF 6.2
    • Fulgurate HCF-Repetition Frequency 34 kHz, 120 W at 500 Ω, CF 7.0
    • Randomized Spray - Randomized Repetition Frequency
    • 34 kHz < f < 50 kHz, 120 W at 500 Ω, CF 8.0
  • BIPOLAR : Pure Sine wave 440 kHz
    • Micro -Lower output voltage, 95 W at 100 Ω, CF 1.5
    • Macro - Higher output voltage, 95 W at 100 Ω, CF 1.5
  • SALINE RESECTION :
    • SIX Modes
    • Saline Cut Modes: 390 kHz
    • Cut I : Continues output 300 W at 100 Ω, CF 1.5, Low Volt
    • Cut II: Continues output 300 W at 100 Ω, CF 1.5, Medium Volt
    • Cut III : Continues output 300 W at 100 Ω, CF 1.5, High Volt
    • Saline Coag Modes: 440kHz
    • Soft: Continues output 200 W at 100 Ω, CF 1.5, Low Voltage
    • Standard: Continues output 200 W at 100 Ω, CF 1.5, Medium Volt
    • Force: Continues output 200 W at 100 Ω, CF 1.5, High Volt
  • FEEDBACK SYSTEM:
    • 3 Microprocessor Controlled 6SENSE Technology with sampling rate above 4000 sense/second
    • Maximum output power deviation < 15% or 5 watts, whichever is greater at any setting with PER-98

Description

  • Saline Resection Mode : Saline Plasma Bipolar Cut & Coag with reusable Bipolar working element & loops.
  • Bipolar Cut & Coag Mode : Bipolar Coaglution & Cutting of Tissue by Shalya Bipolar Scalpel (Desiccator)
  • 6SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology.
  • PREM : Patient Return Electrode Monitoring gives an Alarm providing safety against the Return Electrode site burns.
  • Tissue ReHold Alarm : “CL rEHOLd" (Close Rehold) is given if Insert is closed & “OP rEHOLd"(Open Rehold) in case of open.
  • Randomized SPRAY Coag : Homogeneous, superficial, faster Coagulation over larger area.
  • Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any.
  • Upgradability : Argon Beam Coagulation, Ultrasonic Aspirator, Smoke Evacuator, Suction Irrigation module.
  • User Programmable : THIRTY Surgical Programs help in setting the system after power ON.
  • BiCoag Alarm : Audio feedback after completion of Bipolar Coag, reduces charring and sticking.
  • Pulse/Endo Cut : Tissue feedback Pulse Interval controlled Pulse Cut for Polypectomy & Papillotomy.
  • Remote Power Settings : Change mode and power from sterile field by normal Handswitch Pencil.
  • AutoBip (Optional) : Automatic Start & Stop of Bipolar current by tissue sensing without foot switch activation.
  • Foot Switches / Pedals : Explosion Proof (Fire Resistance) and Water Proof Foot Pedals
  • Time Out Function (Optional) : Automatically stops the HF output if prolong unintended activation.
  • Surgical Applications : Useful for wide range of surgical application as : Plastic, Neuro, ENT, Spine, Opthal, Laparo Surgery, Endo, GI, Ortho, Open & General Surgery, Onco, Gynecology, Hernia,GI Endocut, Papillotomy, Polypectomy, Under Water, Urology, Gynec TCRE, Hysteroscopy, Thoracotomy, Cardio Thoracic. Saline Plasma Bipolar Resection : Bipolar TURP/ TCRE / Hysteroscopy / Arthroscopic Surgery

Quick Contact 👋